Enhances usability with an intuitive text menu and optional multi-color backlighting for improved visibility and orientation. This option is ideal for those who value a balance between functionality and ease of use.
Connection
1"
Inlet/Outlet Fittings
¾" to 1.5” NPS
Cycles
up to 9
Service flow rate
6.12
m³/h
Tank Applications
6" - 21"
Diameter
Operating pressures
1.4 - 8.6
bar
FLOW RATES
Service @ 15 psi/1 bar drop (includes bypass and meter) - 102 lpm (6.12 m3/h) (27 gpm)
Backwash @ 25 psi/1.7 bar drop (includes bypass) - 102 lpm (6.12 m3/h) (27 gpm)
OPERATING PRESSURES
Minimum/Maximum: 20 - 125 psi (1.4 - 8.6 bar)
OPERATING TEMPERATURES
Minimum/Maximum: 40º - 110º F (4º – 43º C)
METER
Accuracy: ± 5%
Flow Rate Range: 0.95 - 102 lpm
Volume Range: 0.02 - 5,700 m3
Totalizer: 1 m3 - 99,999 m3
DIMENSIONS & WEIGHT
Distributor Pilot - 1.050" OD Pipe (¾" NPS)
Drain Line - ¾" or 1" NPT
Brine Line - 3/8" or ½" OD Poly Tube
Mounting Base - 2 ½"- 8 NPSM
Height From Top Of Tank - 7 3/8" (187 mm)
Weight - 4.5 lbs (2 kg)
TANK APPLICATIONS
Water Softener: 6" - 21" Diameter
Water Filter (1): 6" - 21" Diameter
(1) Filter tank size calculated @ 10 gpm of backwash per square foot of bed area / 407 lpm per square meter of bed area.
CYCLES OF OPERATION
Choose up to nine regeneration cycles, in any order, with a wide range of available values:
Backwash: 1 - 120 minutes
Rinse: 1 - 120 minutes
Pause (service): 1 - 480 minutes
Brine (co-current): 1 - 180 minutes
Refill (softener): 0.05 - 90.00 Kg
Refill (filter): 0.2 - 76.00 Liters
Options: Backwash Filter, Bypass, Weather Cover
Compatible with the following typical concentrations of regenerants or chemicals: Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, chlorine and chloramines