The Clack® CI valve, made in the United States, is designed to work with ion-exchange materials. It features a direct-flow regeneration type and backwash function. Regeneration can be delayed, instant, or both.
Connection
1.5"
FLOW RATES
Service @ 15 psi/1 bar drop (includes bypass and meter) - 265 lpm (15.9 m3/h) (70 gpm)
Backwash @ 25 psi/1.7 bar drop - 197 lpm (11.8 m3/h) (52 gpm)
OPERATING PRESSURES
Minimum/Maximum: 20 - 125 psi (1.4 - 8.6 bar)
OPERATING TEMPERATURES
Minimum/Maximum: 40º - 110º F (4º – 43º C)
METER
Accuracy: ± 5%
Flow Rate Range: 2 - 284 lpm (0.5 - 75 gpm)
Volume Range: 0.02 - 5,700 m3
Totalizer: 1 m3 - 99,999 m3
DIMENSIONS & WEIGHT
Distributor Pilot
Valve bodies with 1.5" Female BSPT Inlet & Outlet - 50 mm OD
Valve bodies with 1.5" Female NPT Inlet & Outlet - 1.90” OD (1.5" NPS)
Drain Line Connection(2) - 1.25” Female NPT
Adapter Included - 3⁄4" Male NPT Elbow
Brine Line Connection - ¾” Female NPT
Adapter Included - ½” OD Poly Tube Compression
Mounting Base - 4" - 8 UN
Height From Top Of Tank - 191 mm (7.5”)
Weight - 21 lbs (9.5 kg)
TANK APPLICATIONS
Water Softener: 6" - 24" Diameter
Water Filter (2): 6" - 30" Diameter
CYCLES OF OPERATION
Choose up to nine regeneration cycles, in any order, with a wide range of available values:
Backwash: 1 - 120 minutes
Rinse: 1 - 120 minutes
Pause (service): 1 - 480 minutes
Brine (co-current): 1 - 180 minutes
Brine (counter-current): 1 - 180 minutes
Refill (softener): 0.05 - 90.00 Kg
Refill (filter): 0.2 - 76.00 Liters / .1 - 99 minutes
Options: Backwash Filter, Bypass, Weather Cover
Compatible with the following typical concentrations of regenerants or chemicals: Sodium chloride, potassiumchloride, potassium permanganate, sodium bisulfite, chlorine and chloramines
(1) See Distributor Pilot.
(2) Casting comes with a 1.25" Female NPT drain connection. An adapter is provided to accept existing WS1 drain line 3⁄4" Male NPT flow controls up to 38 lpm (10 gpm). Other drain line flow controls are available for flow rates above 38 lpm (10 gpm).
(3) Filter tank size calculated @ 407 lpm per m2 of bed area/10 gpm of backwash per square foot of bed are
We are actively seeking B2B partners to drive business development internationally. If your organization aims for collaborative growth, we invite you to connect with us through this form. Together, we can achieve mutual success and foster innovation.