The multilingual Clack® CE control valve, was collaboratively developed by Clack® and Ecosoft engineers to work seamlessly with the ECOMIX® filtering material. It features a direct-flow regeneration type and backwash function. Regeneration can be delayed, instant, or both.
Connection
1.25"
FLOW RATES
Service @ 15 psi/1 bar drop (includes bypass and meter) - 129 lpm (7.7 m3/h) (34 gpm)
Backwash @ 25 psi/1.7 bar drop (includes bypass) -c121 lpm (7.3 m3/h) (32 gpm) (1)
OPERATING PRESSURES
Minimum/Maximum: 20 - 125 psi (1.4 - 8.6 bar)
OPERATING TEMPERATURES
Minimum/Maximum: 40º - 110º F (4º – 43º C)
METER
Accuracy: ± 5%
Flow Rate Range: 0.95 - 129 lpm
Volume Range: 0.02 - 5,700 m3
Totalizer: 1 m3 - 99,999 m3
DIMENSIONS & WEIGHT
Distributor Pilot - 1.32" OD Pipe (1" NPS) or 32 mm OD
Drain Line - ¾" or 1" NPT
Brine Line - 3/8" or ½" OD Poly Tube
Mounting Base - 2 ½"- 8 NPSM
Height From Top Of Tank - 7 3/8" (187 mm)
Weight - 4.5 lbs (2 kg)
TANK APPLICATIONS
Water Softener: 6" - 21" Diameter
Water Filter (1): 6" - 24" Diameter
CYCLES OF OPERATION
Choose up to nine regeneration cycles, in any order, with a wide range of available values:
Backwash: 1 - 120 minutes
Rinse: 1 - 120 minutes
Pause (service): 1 - 480 minutes
Brine (co-current): 1 - 180 minutes
Refill (softener): 0.05 - 90.00 Kg
Refill (filter): 0.2 - 76.00 Liters
Options: Backwash Filter, Bypass, Weather Cover
Compatible with the following typical concentrations of regenerants or chemicals: Sodium chloride, potassiumchloride, potassium permanganate, sodium bisulfite, chlorine and chloramines
(1) Filter tank size calculated @ 10 gpm of backwash per square foot of bed area / 407 lpm per square meter of bed area
We are actively seeking B2B partners to drive business development internationally. If your organization aims for collaborative growth, we invite you to connect with us through this form. Together, we can achieve mutual success and foster innovation.