The Clack® CI valve, made in the United States, is designed to work with ion-exchange materials. It features a direct-flow regeneration type and backwash function. Regeneration can be delayed, instant, or both.
Connection
1.25"
FLOW RATES
Service @ 15 psi/1 bar drop (includes meter, bypass, and 1.25" fitting kit) - 129 lpm (7.7 m3/h) (34 gpm)
Backwash @ 25 psi/1.7 bar drop - 121 lpm (7.3 m3/h) (32 gpm) (1)
OPERATING PRESSURES
Minimum/Maximum: 20 - 125 psi (1.4 - 8.6 bar)
OPERATING TEMPERATURES
Minimum/Maximum: 40º - 110º F (4º – 43º C)
METER
Accuracy: ± 5%
Flow Rate Range: 0.95 - 129 lpm
Volume Range: 0.02 - 5,700 m3
Totalizer: 1 m3 - 99,999 m3
DIMENSIONS & WEIGHT
Distributor Pilot - 1.32" OD Pipe (1" NPS) or 32 mm OD
Drain Line - ¾" or 1" NPT
Brine Line - 3/8" or ½" OD Poly Tube
Mounting Base - 2 ½"- 8 NPSM
Height From Top Of Tank - 7 3/8" (187 mm)
Weight - 4.5 lbs (2 kg)
TANK APPLICATIONS
Water Softener: 6" - 21" Diameter
Water Filter (2): 6" - 24" Diameter
CYCLES OF OPERATION
Choose up to nine regeneration cycles, in any order, with a wide range of available values:
Backwash: 1 - 120 minutes
Rinse: 1 - 120 minutes
Pause (service): 1 - 480 minutes
Brine (co-current): 1 - 180 minutes
Brine (counter-current): 1 - 180 minutes
Refill (softener): 0.05 - 90.00 Kg
Refill (filter): 0.2 - 76.00 Liters
Options: Backwash Filter, Bypass, Weather Cover
Compatible with the following typical concentrations of regenerants or chemicals: Sodium chloride, potassiumchloride, potassium permanganate, sodium bisulfite, chlorine and chloramines
(1) Acquired by use of external drain line flow control.
(2) Filter tank size calculated @ 10 gpm of backwash per square foot of bed area / 407 lpm per square meter of bed area.
We are actively seeking B2B partners to drive business development internationally. If your organization aims for collaborative growth, we invite you to connect with us through this form. Together, we can achieve mutual success and foster innovation.