Results
Close (esc)
Configuration
Standart filter
Compact type
OnlyVolume
0
Ecomix® C volume
50l (2 bags)
Tank size
1252
Brine tank size
140l
Control valve
Clack WS1 or alternative
DLFC Clack®
042
Injector Clack®
F (blue)
Parameters
Service flow rate
1,8m³/h
Backwash flow rate
12520.72-1.0m³/h
Volume Capacity
3.75m³
Interval between regenetations
5 day
Consumption of salt for regeneration
5kg
Water consumption for regeneration
0,5 m³
Monthly salt consumption
360 kg (14.4 bags)
Service life of Ecomix® C
5 years
Programming setting and regeneration stages
Filter capacity
1500 ppm CaCO₃
Day overide
10 days
Type of regenetation
delayed
Hardness
300 ppm CaCO₃
01 backwash
10 min
02 rinse with brine
60 min
03 backwash
1 min
04 fast rinse
10 min
05 brine tank filling
10 min
01 backwash
10 min
02 rinse with brine
60 min
03 backwash
1 min
04 fast rinse
10 min
05 brine tank filling
10 min

Download results 

Super softener

01
Step
02
Step
03
Step
Select Home Configuration

Peak water usage:
1.8 m³/h
Select Water Consumption

Average water consumption in Europe is 150 liters per person.
 
Monthly water consumption:
13.5 m³/month
Continue
Water test
Input water quality parameters from analysis.
Hardness

Manganese
ppm
Ammonium
ppm
Iron
ppm

ppm
Continue
Select a filter type
Type of Ecomix
 
Continue
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Simple solution for 5 problems

01
Hardness

ECOMIX® softens water with hardness up to 45 gpg (750 mg/L CaCO₃).

02
Iron

ECOMIX® reduces common types of iron: ferrous, organic, and colloidal. Influent iron concentration must not exceed 15 mg/L.

03
Manganese

ECOMIX® is one of the most reliable means for manganese removal. Influent manganese concentration must not exceed 3 mg/L.

04
Natural organic matter

ECOMIX® is a proven technology to remove tannins and other natural organic compounds. Maximum allowed influent Chemical Oxygen Demand concentration is 20 mg/L O₂.

05
Ammonium

Maximum allowed ammonium concentration is 4 mg/L.

Certified lead free products
Certified in compliance with the NSF/ANSI 44/61/372 standards

Why ECOMIX®

How Works

01
 
Get ready-to-use ECOMIX® media in the bag
02
 
Put the media in a regular
softener
03
 
Regenerate the system,
and ECOMIX® will self-classify in 5-layer bed
04
Use and regenerate ECOMIX® system like you would regular softener
01
 
Get ready-to-use ECOMIX® media in the bag
02
 
Put the media in a regular
softener
03
 
Regenerate the system,
and ECOMIX® will self-classify in 5-layer bed
04
Use and regenerate ECOMIX® system like you would regular softener
01
 
Get ready-to-use ECOMIX® media in the bag
02
 
Put the media in a regular
softener
03
 
Regenerate the system,
and ECOMIX® will self-classify in 5-layer bed
04
Use and regenerate ECOMIX® system like you would regular softener
Inert resin reduces oxidized iron
FerroSorb reduces iron and manganese
HumiSorb reduces organic impurities
Cation exchange resin softens water
Quartz sand ensures uniform flow across the vessel
01
 
Get ready-to-use ECOMIX® media in the bag
02
 
Put the media in a regular
softener
03
 
Regenerate the system,
and ECOMIX® will self-classify in 5-layer bed
04
Use and regenerate ECOMIX® system like you would regular softener
Salt Tablets
 
 
 
 

In Resintail Environment

Footprint
0.4 m2
Saves up to
66%
of space
Salt consumption
5 kg
Consumes
70%
less salt
Water consumption
0.5 m3
Discharges
63%
less water
Cost
$1800
Is
50%
less expensive
Traditional
Footprint
1.1 m2
Salt consumption
17 kg
Water consumption
1.3 m3
Cost
$3600

Removal of iron and manganese

FerroSorb is a proprietary sorption material for iron and manganese removal

FerroSorb mechanism of action

Iron And Manganese Reduction

Mechanism of iron and manganese reduction: Adsorption > Oxidation > Active Layer Formation > Autocatalytic Oxidation. Due to this process, FerroSorb removes most common species of iron in raw water: ferrous, ferric, organic, and colloidal. Active layer of Ferrosorb contains active sites for manganese removal.

Alternative To Aeration And Chlorination

Best efficiency of Ecomix is achieved when raw water is fed directly to Ecomix softener. Do not use oxidative pre-treatment before the Ecomix system.

ECOMIX® regeneration

Regenerated As A Softener

Ecomix® is regenerated with the same steps as normal softeners: backwash, brine, rinse, fill. Calcium and magnesium ions are displaced from the cation exchange resin matrix with sodium ions.

Regeneration of FerroSorb

Iron and manganese are removed during backwash stage by surface scour mechanism in fluidized bed.

Removing Natural Organic Matter

HumiSorb is a proprietary sorption material for removal of natural organic matter (reducing color and NOM)
Organic compounds are removed by the mechanism of hydrophobic and electrostatic interactions
HumiSorb beads after service
Fresh HumiSorb beads

TECHNICAL SPECIFICATION

Minimum bed depth
20 inch
Service flow rate
20-25 m/h
Salt consumption
100 g/L
Backwash flow rate
10-15 m/h

INSTALLATION SCHEMATIC

.
Home Configuration
Bathrooms
2
Kitchen
1
Peak water usage:
1.8 m³/h
Water Consumption
residents
3
liters per day
150
Monthly water consumption:
13.5 m³/month
Configuration
Standart filter
Compact type
OnlyVolume
0
Ecomix C volume
50l (2 bags)
Tank size
1252
Brine tank size
140l
Control valve
Clack WS1 or alternative
DLFC Clack®
042
Injector Clack®
F (blue)
Parameters
Service flow rate
1,8m³/h
Backwash flow rate
12520.72-1.0m³/h
Volume Capacity
3.75m³
Interval between regenetations
5 day
Consumption of salt for regeneration
5kg
Water consumption for regeneration
0,5 m³
Monthly salt consumption
360 kg (14.4 bags)
Service life of Ecomix C
5 years
Programming setting and regeneration stages
Filter capacity
1500 ppm CaCO₃
Day overide
10 days
Type of regenetation
delayed
Hardness
300 ppm CaCO₃
01 backwash
10 min
02 rinse with brine
60 min
03 backwash
1 min
04 fast rinse
10 min
05 brine tank filling
10 min
01 backwash
10 min
02 rinse with brine
60 min
03 backwash
1 min
04 fast rinse
10 min
05 brine tank filling
10 min