All media (1)
Video (1)
Dimensions
Video
Image Size
DIMENSIONS, H×W×D:
2178 × 6933 × 2270
mm
Filter weight
1700
kg
All media (1)
Video (1)
Dimensions
Ecosoft MO36 industrial reverse osmosis system is a turnkey solution for industrial water challenges, that includes pilot studies, engineering and manufacturing, commissioning and maintenance.
Ecosoft reverse osmosis systems are used in food and pharmaceutical industry, energy, chemical, semiconductor manufacturing, steam boilers and other industrial applications.
Energy efficiency with Grundfos pump
Reliable performance with quality components and engineering
Individual project evaluation per request
ISO 9001 certified factory
CE marked and confirmed to be safe in accordance with EC New Approach Directives
Show More Features
Permeate capacity
36–42
m³/h
Recovery
75
%
Maximum TDS
3000
mg/L
Influent flow demand (service)
50–60
m³/h
Operating pressure
8..12
bar
Power consumption
22
kW
Product
Image Size
DIMENSIONS, H×W×D:
2178 × 6933 × 2270
mm
Filter weight
1700
kg
Equipment
- Grundfos® CR 45-4-2 high-pressure pump: 1 pc
- 8040-6 membrane vessels: 6 pcs
- Stainless steel housing with 7 PP 2,5 × 40″ filter: 2 pcs
- Motorized feed water in, flush out butterfly valves: 2 pcs
- Balancing concentrate reject, concentrate recycle valves: 2 pcs
- Electrical cabinet with Ecosoft controller: 1 set
- Piping, instrumentation: 1 set
- Steel frame: 1 set
Options
- Filmtec™ XLE-440 / ECO PRO-440 or Ecosoft ELP-8040 membranes
- Dosing pump for antiscalant or other RO chemicals
- Permeate inlet for permeate membrane rinse
- Raw water blending line
Сonnections
- Influent water: DN100 (flange)
- Permeate: DN80 (flange)
- Concentrate: DN100 (flange)
- CIP inlet: DN80 (flange)
- CIP return: DN80 (flange)
Technical data
- Permeate capacity¹: 36 m³/h
- Permeate recovery²: 75%
- Maximum TDS: 3000 mg/L
- Influent flow demand: 50…60 m³/h (service)
- Operating pressure: 8…12 bar
- Maximum pressure: 14 bar
- Electrical requirements: 380...400 V, 50 Hz (3 ph)
- Electrical power: 22 kW
- Prefilter rating: 5 μm
¹ depends on feed water TDS, temperature, and permeate recovery
² for low scaling/fouling water
Feed water requirements
- TDS: 3000 mg/L
- hardness: 150 mg/L CaCO₃
- iron: 0.1 mg/L
- manganese: 0.05 mg/L
- hydrogen sulfide: none
- silicate: 20 mg/L
- residual chlorine: 0.1 mg/L
- SDI: 5
- chemical oxygen demand: 4 mg/L O₂