Ecosoft MO 12000 commercial reverse osmosis system

Article : M10VCTFWE
  • Up to 3200 gal of pure water per day  ?
  • Effective solution for problem water  ?
  • Original eye-catching design and compact size  ?
  • Simple maintenance  ?
  • Low energy consumption  ?
€5,600
5600

You get all the advantages of perfect quality water with Ecosoft MO 12 000 commercial reverse osmosis system. It is the most advanced and effective way to remove up to 99.8% of impurities, including bacteria and viruses. Reverse osmosis is an eco-friendly and economic way to get safe drinking water. 

The system is a compact and entirely functionally complete module.

Model features


shield.png
100% protection

drop.png
Up to 12 000 liters of purified water per day

worker.png
Continuous monitoring of the purified water quality   

illumination.png
Compact and fully automated

quality.png
High-quality components from leading manufacturers

no-sound.png
Low noise and vibration high pressure pump

OS 5000 controller for efficient and independent operation

Controller OS 5000 is designed for automatic or manual operation of reverse osmosis systems and provides: 

controller.jpg
  • switching on and off of the system according to the level of water in the storage tank; 

  • automatic hydraulic flushing of membranes; 

  • stopping and showing alert when fault conditions occur (low feed water pressure, high product water conductivity); 

  • monitoring and displaying electrical conductivity and temperature.

Maintenance

For correct and effective system operation it is necessary to do the following:
  • Change sediment replacement filters -at least once every 3 months.

Sediment filter protects the RO membrane from large impurities such as sand, clay particles, etc. Delay in replacing them can damage or destroy the membrane.

  • Carry out chemical cleaning of the RO membrane -at least twice a year.

CIP should be carried out in case of deteriorating purified water quality or capacity reduction. CIP is carried out by using a chemical cleaning unit and cleaning chemicals.

  • Keep a register of maintenance, system operational parameters and water quality.

A history of maintenance and operation of the system will allow the most efficient and timely change replacement filters, chemical washing of membranes and other system maintenance activities.

Who is the product for?

Ecosoft MO 12 000 RO system is designed for water purification in:

— hotels, cafes, and restaurants;      

— brewery and bakery;    

— laboratories and workshops;    

— car wash;

— small scale industrial processes;

— 
steam boilers, heating and cooling systems.

Hartford-Baking-Co-19_1.jpg

iStock_15724475_SMALL.jpg


M6VCTFWE_MO-6000_3.png

Feed water goes through sediment prefilters to remove particles.

If using antiscalant for hard water then it is injected before the prefilters, so the chemical is mixed with water more thoroughly. 

High pressure pump feeds the prefiltered water into the membrane array. Inside the membranes, feed water is separated into purified water (permeate) and brine with retained impurities (concentrate). 

Ecosoft RO systems feature built-in concentrate recycle, sending part of the concentrate back to the pump. Recycle flow control and drain flow control work to sustain the operating pressure and the recycle/waste ratio. 

Operating pressure is variable within allowed range. Higher pressure produces higher permeate flow rate and/or recovery. Proper operating pressure and recycle/waste must be set up during commissioning. 

Ecosoft RO system runs in a completely automated fashion. The system stops to standby when pure water tank is full. Automated membrane rinse occurs every time before standby, with preprogrammed intervals during standby and service. 

If any of below conditions occur, the system switches off and displays failure alert: 

iso-exclamation-warning-symbol-is-2002(1).png low feed water pressure 

iso-exclamation-warning-symbol-is-2002(1).png high operating pressure 

iso-exclamation-warning-symbol-is-2002(1).png high permeate conductivity 

iso-exclamation-warning-symbol-is-2002(1).png phase or voltage failure 



drops.png

Pre-filters

Sediment filters protect membrane from large impurities such as sand, clay particles, etc. Failure to replace the filters in due time can damage or destroy the membrane. In order to avoid such critical situations, we recommend changing the replacement filter at least once every 3 months.

jerrycan (1).png

Clean-in-place

In case of worsening quality of the treated water or a decrease in productivity, it is necessary to conduct chemical cleaning of the RO membrane with a CIP-station and special reagents. To obtain purified water of high quality, we recommend chemical cleaning  at least twice a year.

no-water.png

Long downtime

If you do not plan to use the system for a long time, it is necessary to shut off the water supply to the system, and soak the membrane elements in a special preservative solution - this will keep the membranes working when idle.


organize.png

Operating log

It is recommended to keep maintenance register for the reverse osmosis system and a log book of the system performance and water quality. The data will help to remember to replace the filters, chemical cleaning of membranes and other maintenance operations connected to the system service.



Operational characteristics and technical data

Parameter

Units

Value

Flow capacity at 15°С1

m3/hour

0.45

RO elements

1

XLE-4040

Power supply


230 V, 50 Hz

Pump power

kW

0.67

Inlet pressure

bar

2...42

Operation pressure in the RO membrane

bar

7...10

Water consumption in operating mode

m3/hour

0.6...1.0

Water consumption in flush mode

m3/hour

1.8...2.3

Connection port sizes:

  • feed water

  • permeate

  • concentrate



½"

½"

½"

System dimensions (H x W x D), mm

mm

540 х 405 х 1450     

1 capacity of the RO system depends on feed water composition and its temperature

for stable operation requires a constant pressure (+/- 0.5 bar) in the specified range

Feed water requirements

Parameter

Units

Value

Temperature of feed water

°С

4...30

Residual chlorine, max

mg/L (ppm)

0.1

Hardness

meq/L

3 (301)

Iron  

mg/L(ppm)

0.1 (0.51)

Manganese

mg/L(ppm)

0.05 (0.11)

Silicate

mg/L(ppm)

20 (2501)

Chemical oxygen demand

mg O2/L (ppm O2)

when using antiscalant, hardness and silica have higher limits

2 for reliable operation stable pressere needed (+/- 0.5 bar)

Components of the system

  • Dow Filmtec™ XLE-4040 membrane

  • Grundfos high-pressure pump

  • European solenoid valves

  • Multifunctional controller

  • Conductivity sensor

  • Sediment filter

  • High and low-pressure switches

  • Float switch

  • Regulated discharge and recycle flow meter

  • Vibration resistant pressure gauges

  • Frame with unique design

Options

  • Dow Filmtec™ LC LE-4040 membranes

  • Membrane rinse with permeate

  • Raw water blending

Cookies

This Platform uses first- and third-party cookies to improve your experience and our services, analyzing browsing within the Platform. By continuing to browse you are accepting their use.

You can find more information or learn how to change the settings in our Cookie Policy.

By continuing to browse you are accepting their use.

Also you confirm that you have read and understood the Privacy Policy.

x^